Commit Graph

10 Commits

Author SHA1 Message Date
b58b1b3953 [metrics] Make DorisMetrics to be a real singleton (#3417) 2020-05-04 09:20:53 +08:00
72f3082358 [Metrics] Add some metrics for container size in BE (#3246)
We can observe the workload of BE, and also it's a way to check
whether there is any problem in BE, like some container increase
too large and lead to OOM.

This patch add the following metrics:
```
Name                                   Description
rowset_count_generated_and_in_use      The total count of rowset id generated and in use since BE last start
unused_rowsets_count                   The total count of unused rowset waiting to be GC
broker_count                           The total count of brokers in management
data_stream_receiver_count             The total count of data stream receivers in management
fragment_endpoint_count                The total count of fragment endpoints of data stream in management, should always equal to data_stream_receiver_count
active_scan_context_count              The total count of active scan contexts
plan_fragment_count                    The total count of plan fragments in executing
load_channel_count                     The total count of load channels in management
result_buffer_block_count              The total count of result buffer blocks for queries, each block has a limited queue size (default 1024)
result_block_queue_count               The total count of queues for fragments, each queue has a limited size (default 20, by config::max_memory_sink_batch_count)
routine_load_task_count                The total count of routine load tasks in executing
small_file_cache_count                 The total count of cached small files' digest info
stream_load_pipe_count                 The total count of stream load pipes, each pipe has a limited buffer size (default 1M)
tablet_writer_count                    The total count of tablet writers
brpc_endpoint_stub_count               The total count of brpc endpoints
```
2020-04-25 16:13:39 +08:00
4a7a88ede1 [LSAN] Fix some memory leak detected by LSAN (#3326) 2020-04-22 22:59:44 +08:00
2ed184e06a Add config: tablet writer open rpc timeout (#3258) 2020-04-03 16:43:56 +08:00
3e6dfa31c4 [UnitTest] Fix BE unit test randomly failed (#2970)
* fix http server related unit test failed due to http port has been used
* fix unit test failed in DEBUG build type
2020-02-21 22:21:02 +08:00
62acf5d098 Limit the memory usage of Loading process (#1954) 2019-10-15 09:26:20 +08:00
58801c6ab0 Support converting RowBatch and RowBlockV2 to/from Arrow (#1699) 2019-08-27 11:30:00 +08:00
69af50aa8c Time zone related BE function (#1598)
Details can be found in time-zone.md document
2019-08-12 20:57:59 +08:00
0694b6a6fa Fix bugs of Broker load (#1546)
Use same UUID as query ID and load ID of a load execution plan.
Each load execution plan has a load ID, and as a plan, there is also a query ID.
We can use same UUID as query ID and load ID, for tracing the load process more easily.

Change the load ID when retrying a load execution plan.
When a load execution plan retry, the load ID should be changed, otherwise BE can not
distinguish the old and new load requests.

Cancel the running loading task when cancelling the broker load.
When user cancel a broker load, the running loading task should also be cancelled, or
it may occupies the worker thread for a long time.

Remove the unnecessary query report when doing load execution plan.
Only the last query report is needed.

Add a new BE config tablet_writer_rpc_timeout_sec.
It is used for RPC of tablet sink. The default is 600 seconds. which is long enough for flushing
about 6GB data. The long timeout config will reduce the possibility of encountering fail to send batch error when loading.

Use streaming_load_max_mb instead of mini_load_max_mb in BE config.

Add more logs for tracing a broker load process easily.
2019-07-27 20:17:05 +08:00
0d48a3961c Refactor Storage Engine (#1478)
NOTE: This patch would modify all Backend's data.
And this will cause a very long time to restart be.
So if you want to interferer your product environment,
you should upgrade backend one by one.

1. Refactoring be is to clarify the structure the codes.
2. Use unique id to indicate a rowset.
   Nameing rowset with tablet_id and version will lead to
   many conflicts among compaction, clone, restore.
3. Extract an rowset interface to encapsulate rowsets
   with different format.
2019-07-15 21:18:22 +08:00