MXS-1679 Check for existence of master before continuing failover checks

Seems to fix the issue with MaxScale detecting an old master down event.
This commit is contained in:
Esa Korhonen 2018-03-14 17:23:56 +02:00
parent dad8e5da59
commit 2178667245

View File

@ -3330,49 +3330,50 @@ void check_maxscale_schema_replication(MXS_MONITOR *monitor)
bool mon_process_failover(MYSQL_MONITOR* monitor, uint32_t failover_timeout, bool* cluster_modified_out)
{
ss_dassert(*cluster_modified_out == false);
if (config_get_global_options()->passive ||
(monitor->master && SERVER_IS_MASTER(monitor->master->server)))
{
return true;
}
bool rval = true;
MXS_CONFIG* cnf = config_get_global_options();
MXS_MONITORED_SERVER* failed_master = NULL;
if (!cnf->passive)
for (MXS_MONITORED_SERVER *ptr = monitor->monitor->monitored_servers; ptr; ptr = ptr->next)
{
for (MXS_MONITORED_SERVER *ptr = monitor->monitor->monitored_servers; ptr; ptr = ptr->next)
if (ptr->new_event && ptr->server->last_event == MASTER_DOWN_EVENT)
{
if (ptr->new_event && ptr->server->last_event == MASTER_DOWN_EVENT)
if (failed_master)
{
if (failed_master)
{
MXS_ALERT("Multiple failed master servers detected: "
"'%s' is the first master to fail but server "
"'%s' has also triggered a master_down event.",
failed_master->server->unique_name,
ptr->server->unique_name);
return false;
}
MXS_ALERT("Multiple failed master servers detected: "
"'%s' is the first master to fail but server "
"'%s' has also triggered a master_down event.",
failed_master->server->unique_name,
ptr->server->unique_name);
return false;
}
if (ptr->server->active_event)
if (ptr->server->active_event)
{
// MaxScale was active when the event took place
failed_master = ptr;
}
else if (monitor->monitor->master_has_failed)
{
/**
* If a master_down event was triggered when this MaxScale was
* passive, we need to execute the failover script again if no new
* masters have appeared.
*/
int64_t timeout = SEC_TO_HB(failover_timeout);
int64_t t = hkheartbeat - ptr->server->triggered_at;
if (t > timeout)
{
// MaxScale was active when the event took place
MXS_WARNING("Failover of server '%s' did not take place within "
"%u seconds, failover needs to be re-triggered",
ptr->server->unique_name, failover_timeout);
failed_master = ptr;
}
else if (monitor->monitor->master_has_failed)
{
/**
* If a master_down event was triggered when this MaxScale was
* passive, we need to execute the failover script again if no new
* masters have appeared.
*/
int64_t timeout = SEC_TO_HB(failover_timeout);
int64_t t = hkheartbeat - ptr->server->triggered_at;
if (t > timeout)
{
MXS_WARNING("Failover of server '%s' did not take place within "
"%u seconds, failover needs to be re-triggered",
ptr->server->unique_name, failover_timeout);
failed_master = ptr;
}
}
}
}
}