Move items from MonitorWorker to MonitorWorkerSimple

MonitorWorker only enforces the use of a worker thread but otherwise
does not define how the monitor is implemented.
This commit is contained in:
Esa Korhonen
2019-04-11 15:20:05 +03:00
parent 2bc0b9c875
commit 75c0ac5323
4 changed files with 50 additions and 22 deletions

View File

@ -2280,7 +2280,6 @@ bool Monitor::check_disk_space_this_tick()
MonitorWorker::MonitorWorker(const string& name, const string& module)
: Monitor(name, module)
, m_master(NULL)
, m_thread_running(false)
, m_shutdown(0)
, m_checked(false)
@ -2354,7 +2353,6 @@ bool MonitorWorker::start()
bool started = false;
if (m_checked)
{
m_master = NULL;
m_loop_called = get_time_ms() - m_settings.interval; // Next tick should happen immediately.
if (!Worker::start())
{
@ -2545,6 +2543,18 @@ void MonitorWorker::flush_server_status()
}
}
void MonitorWorkerSimple::pre_loop()
{
m_master = nullptr;
load_server_journal(&m_master);
// Add another overridable function for derived classes (e.g. pre_loop_monsimple) if required.
}
void MonitorWorkerSimple::post_loop()
{
}
void MonitorWorkerSimple::pre_tick()
{
}
@ -2555,6 +2565,7 @@ void MonitorWorkerSimple::post_tick()
void MonitorWorkerSimple::tick()
{
check_maintenance_requests();
pre_tick();
const bool should_update_disk_space = check_disk_space_this_tick();
@ -2628,6 +2639,11 @@ void MonitorWorkerSimple::tick()
}
post_tick();
flush_server_status();
process_state_changes();
hangup_failed_servers();
store_server_journal(m_master);
}
void MonitorWorker::pre_loop()
@ -2654,7 +2670,6 @@ bool MonitorWorker::pre_run()
m_thread_running.store(true, std::memory_order_release);
m_semaphore.post();
load_server_journal(&m_master);
pre_loop();
delayed_call(1, &MonitorWorker::call_run_one_tick, this);
}
@ -2707,17 +2722,8 @@ bool MonitorWorker::call_run_one_tick(Worker::Call::action_t action)
void MonitorWorker::run_one_tick()
{
check_maintenance_requests();
tick();
mxb::atomic::add(&m_ticks, 1, mxb::atomic::RELAXED);
flush_server_status();
process_state_changes();
hangup_failed_servers();
store_server_journal(m_master);
}
bool MonitorWorker::immediate_tick_required() const