Distinguish stopped and finished workers
By having a separate FINISHED state and a STOPPED state, it is possible to know at which point in the worker's lifetime an event is done. Posting of messages before a worker is started is allowed but posting them after the worker has stopped is not. This fixes avrorouter related failures and all other failures that stem from worker messages being ignored at startup.
This commit is contained in:
parent
dd944c7302
commit
7673ee685d
@ -300,7 +300,8 @@ public:
|
||||
IDLE,
|
||||
POLLING,
|
||||
PROCESSING,
|
||||
ZPROCESSING
|
||||
ZPROCESSING,
|
||||
FINISHED
|
||||
};
|
||||
|
||||
enum execute_mode_t
|
||||
|
@ -523,9 +523,9 @@ bool Worker::post_message(uint32_t msg_id, intptr_t arg1, intptr_t arg2)
|
||||
|
||||
// TODO: Enable and fix this in develop and/or 2.4: The deletion of rworker_local is done after the
|
||||
// workers have stopped and it triggers this assertion.
|
||||
// mxb_assert(state() != Worker::STOPPED);
|
||||
// mxb_assert(state() != Worker::FINISHED);
|
||||
|
||||
if (state() != Worker::STOPPED)
|
||||
if (state() != Worker::FINISHED)
|
||||
{
|
||||
MessageQueue::Message message(msg_id, arg1, arg2);
|
||||
rval = m_pQueue->post(message);
|
||||
@ -536,7 +536,7 @@ bool Worker::post_message(uint32_t msg_id, intptr_t arg1, intptr_t arg2)
|
||||
|
||||
void Worker::run(mxb::Semaphore* pSem)
|
||||
{
|
||||
mxb_assert(m_state == STOPPED);
|
||||
mxb_assert(m_state == STOPPED || m_state == FINISHED);
|
||||
this_thread.pCurrent_worker = this;
|
||||
|
||||
if (pre_run())
|
||||
@ -550,7 +550,7 @@ void Worker::run(mxb::Semaphore* pSem)
|
||||
|
||||
poll_waitevents();
|
||||
|
||||
m_state = STOPPED;
|
||||
m_state = FINISHED;
|
||||
|
||||
post_run();
|
||||
MXB_INFO("Worker %p has shut down.", this);
|
||||
|
@ -2566,7 +2566,11 @@ bool MonitorInstance::start(const MXS_CONFIG_PARAMETER* pParams)
|
||||
// not exist during program start/stop.
|
||||
mxb_assert(mxs_rworker_get_current() == NULL
|
||||
|| mxs_rworker_get_current() == mxs_rworker_get(MXS_RWORKER_MAIN));
|
||||
mxb_assert(Worker::state() == Worker::STOPPED);
|
||||
|
||||
// This can be a bit confusing as the workers are considered to be "finished" when the stop processing. A
|
||||
// better distinction between workers that temporarily stop and permanently stop should be implemented.
|
||||
mxb_assert(Worker::state() == Worker::STOPPED || Worker::state() == Worker::FINISHED);
|
||||
|
||||
mxb_assert(monitor_state() == MONITOR_STATE_STOPPED);
|
||||
mxb_assert(m_thread_running.load() == false);
|
||||
|
||||
|
Loading…