Add documentation on how to reset the conversion process

The resetting of the conversion process is now documented.
This commit is contained in:
Markus Mäkelä 2018-01-03 09:55:18 +02:00
parent f5484a1011
commit b5914df4f9

View File

@ -199,6 +199,14 @@ the locations of the GTIDs in the .avro files. The _avro-conversion.ini_ contain
the last converted position and GTID in the binlogs. If you need to reset the
conversion process, delete these two files and restart MaxScale.
# Resetting the Conversion Process
To reset the binlog conversion process, issue the `purge` module command by
executing it via MaxAdmin and stop MaxScale. If manually created schema files
were used, they need to be recreated once MaxScale is stopped. After stopping
MaxScale and optionally creating the schema files, the conversion process can be
started by starting MaxScale.
# Example Client
The avrorouter comes with an example client program, _cdc.py_, written in Python 3.