0 cannot be used to indicate failure as 0 will be the waiting
period if we switch to an alternative server.
Also fix some minor issues; failure to initialize all members
and inverted success-check.
Separating the reading of the config from the process of
applying it allows us to use configs around and later apply
them (e.g. when we decide its time to switch master server).
At save time, assert that the configuration as dispersed around
blr and as stored in the config object are identical.
Later its the state from the config object that will be saved.
Alternative masters can now be specified like
CHANGE MASTER TO ...
CHANGE MASTER ":2" TO ...
CHANGE MASTER ":3" TO ...
Now only the data is stored, but it is neither used nor
saved.
This function applies a change master config. Currently is
used from blr_handle_change_master(), and subsequently will
be used when BLR switches to an alternative master.
This type will be used for storing the configuration
specified with CHANGE MASTER at a point where it has been
verified, to the extent possible, that the provided options
are valid.
In order to make it visible that the types contain C++
members, the following types were renamed:
CHANGE_MASTER_OPTIONS -> ChangeMasterOptions
MASTER_SERVER_CNF -> MasterServerConfig
Functions where also changed to take const refs were appropriate.
In order support the possiblity for having multiple alternative
masters for the binlog server, we need to have multiple configs
around.
Originally the config values were stored as 'char *':s, which
would have made the lifetime management of the strings laborious
and error prone.
Now, the options are stored as std::string:s, which makes the
lifetime management a non-issue.
When receiving a command, such as
CHANGE MASTER TO MASTER_HOST = '127.0.0.1' ...
when the value is extracted, the quotes are removed before the value
is returned.
Firstly, BLR does not anyway anywhere enforce that quotes are present
where they should be and, secondly, BLR currently does de-quoting all
over the place and with this change, all those places can be simplified.
The configuration updating in readwritesplit was the inspiration for the
mxs::rworker_local type. Due to this, taking it into use simply means that
the type changes from Config to mxs::rworker_local<Config>.
Given that worker.hh was public, it made sense to make routingworker.hh
public as well. This removes the need to include private headers in
modules and allows C++ constructs to be used in C++ code when previously
only the C API was available.
NamedServerFilter now uses struct sockaddr_in6 to store the source
parameter. If ipv4 addresses are used they are mapped to ipv6 struct,
this allows the usage of both ipv4 and ipv6.
This commit also includes some small refactoring and removing some code
that was not needed anymore.
Since the servers are not modified before or during the wait, the waiting
can be done in the preparation method. This simplifies the actual failover
somewhat, and allows the monitor to keep running normally while waiting for
the log to clear.
By storing the data gathere by readwritesplit inside the session, the
protocol will be aware of the state of the LOAD DATA LOCAL INFILE
execution. This prevents misinterpretation of the data which previously
led to closed connections, effectively rendering LOAD DATA LOCAL INFILE
unusable.
This change is a temporary solution to a problem that needs to be solved
at the protocol level. The changes required to implement this are too big
to add into a bug fix release.
No longer depends on monitor events as the other operations do not
either. The active_event/new_event detection was removed, as these
only protect against a rare situation. A similar feature which
protects all the cluster modifications will be implemented later.
The master reconnection in the binlogrouter used the housekeeper
recursively. This is no longer supported and the delayed worker call
mechanism should be used in its stead.
The maxscale_is_shutting_down function is used to detect when MaxScale
should stop. This fixes a race condition in the code where the workers has
not yet been initialized but a termination signal has been received. It
also replaces the misuse of the service_should_stop variable with a proper
function.
qc_thread_init() must now explicitly be called in every thread
and not just in other threads but the one where qc_process_init()
is called.
This change was caused by QC_INIT_SELF initialization actually
being performed in query_classifier.cc. Before this change, there
actually was a leak in the routing worker running in the main
thread, the query classification cache was created twice.
If a large packet is received, the stack would overflow when the username
size was determined from the packet size. The code must not assume
anything about the size of the packet being read.
Reducint the time the load testing runs for seems to reduce the volume by
the same amount. Given that unit tests are good for catching obvious
mistakes, the test should still be adequate.
In default case MaxScale uses ipv6 for all addresses also mapping ipv4
connections to ipv6. This caused NamedServerFilter to never match these
addresses to the ones defined in source parameter in ipv4 form.
These ipv6-mapped addresses are now transformed to ipv4 so they can be
checked against source parameter list.
Source parameter in NamedServerFilter can now contain a list of source
addresses seperated by comma. This parameter is parsed into a list of ip
addresses and checked against incoming client connections.