When something fails inside dcb_connect we rewind the situation
properly, without calling any of the close functions intended for
shutting down a properly created DCB. That way they can be simplified
and once the reference counting is taken into use it is sufficient to
call dcb_dec_ref(dcb) instead of dcb_free_all_memory().
If a fake event is added to the current dcb, we arrange things so
that it is delivered immediately when the handling of the event(s)
during which the fake event was added, has been performed.
Otherwise the event is delivered via the event loop.
We are only interested in asterisks and column names. Everything
else - integers, floating point numbers, strings, etc. - is of
no interest and not an error.
Raising the signal directly keeps the stack trace smaller. It also makes
sure that the assertion works even if NDEBUG is defined.
The debug assertions are now also printed to stderr to make sure that they
are caught even when running MaxScale directly.
The documentation stated that the users are created with administrative
privileges by default when in fact they were created with read-only
privileges.
Updated documentation generation script and regenerated documentation. Now
all command documentation is generated by using the output of the `help`
commands.
The COM_CHANGE_USER that is sent as a part of the reset process for a
persistent connection did not expect a AuthSwitchRequest packet to be sent
as that implies that the server did not take the authentication fast
path. In this case, an error message needs to be logged stating that the
server requested a different authentication plugin than was expected.
The adminusers test did not properly initialize all subsystems in
MaxScale. The polling and DCB tests weren't updated with the changes to
the DCB closing.
dcb_readq_append()
dcb_readq_prepend()
dcb_readq_set()
dcb_readq_has()
dcb_readq_release()
dcb_readq_get()
dcb_readq_length()
No code but for DCB code itself should directly manipulate the
internals of a DCB. Thesse functions will be taken into use in
protocol modules.
Before each event handler is called, it is checked whether the
dcb has been closed. If it has been, then the event handler is
not called.
The check has to be made before each event handler, because any
event handler can close the dcb.
The original process should use _exit if the forking of the child process
is successful. This makes sure that the exit handlers are called only when
the daemon process exits.
The response handling logic did not always take the last packet for
inspection when a COM_CHANGE_USER was executed. The OK packet will always
be the last one since the COM_CHANGE_USER is the last command that was
sent.
Binlog server: force fake Client DCB close in errorReply. This fixes an
issue when START SLAVE, with new config, is called after a previous one
with errors.
The workers need to be destroyed only after services have been
to ensure that they are around in case the destruction of services
involves the closing of dcbs.
If the current worker id is -1, we do not insist that the dcb
is closed by the owning thread. That will happen only for dcbs
that are created before the workers have been started and hence
it is also ok to close them after the workers have exited.
The automatic reconnection feature of the Connector-C was not
enabled. Enabling it should reduce the amount of false positives that the
monitors pick up.
If the session id is known, it will be logged together with all
messages. If present, the session id appears, enclosed in paranthesis,
right after the message category. E.g.
2017-08-30 12:20:49 warning: (4711) [masking] The rule ...
Conceptually this is a cherry-pick of commit
67efd1daeabbc398b8a8fbc0cd02c2af26e4cb6c (2.2), but too much has
changed to actually be able to cherry-pick that commit.