39 Commits

Author SHA1 Message Date
Markus Mäkelä
27d1be7f96 Merge branch '2.2' of github.com:mariadb-corporation/MaxScale into 2.2 2017-10-03 14:46:14 +03:00
Markus Mäkelä
bd39284f9c Merge branch '2.1' into 2.2 2017-10-03 14:30:06 +03:00
Markus Mäkelä
67ef7bd058 MXS-1367: Take mxs_mysql_query into use
The use of a wrapper function allows automated retrying of the queries
without requiring any changes to the code that uses it.
2017-10-03 10:57:12 +03:00
Johan Wikman
68432bbaa3 Rename MXS_MONITOR::databases to MXS_MONITOR::monitored_servers
More descriptive name. Some local varaibles could now also be
renamed to be more descriptive, but that's for another day.
2017-10-02 15:33:58 +03:00
Johan Wikman
8d03876e3e Rename MXS_MONITOR_SERVERS to MXS_MONITORED_SERVER
An element in a linked list is not a list.
2017-10-02 15:05:17 +03:00
Johan Wikman
e9b2a560b8 MXS-1360 Make it possible to specify thread stack size
It is now possible to specify the thread stack size to be used,
when a new thread is created. This will subsequently be used
for allowing the stack size to be specified for worker threads.
2017-08-14 15:24:16 +03:00
Markus Mäkelä
53bf21f785 MXS-1262: Use monitor journals in all monitors
All monitors now persist the state of the server in a monitor journal
file.

Moved the removal of stale journals into the core and removed them from
the monitor journal interface.
2017-08-11 04:09:08 +03:00
Markus Mäkelä
1f4856cdc5 Merge branch '2.1' into develop 2017-08-03 19:01:32 +03:00
Markus Mäkelä
f7b8744460 Add more error messages to monitors
When the execution of a query fails, the error reported by the Connector-C
and the server where the query was executed is logged.
2017-08-03 15:42:40 +03:00
Johan Wikman
4e73aecdef MXS-1249: Modifications after rebase on develop 2017-06-21 13:28:59 +03:00
Johan Wikman
2a848a63c8 MXS-1249: Also use mxs_mysql_set_version in mmon.c 2017-06-21 13:28:59 +03:00
Johan Wikman
f546a17e77 Update change date of 2.2 2017-06-01 10:24:20 +03:00
Markus Mäkelä
b434c94563 Prevent monitor deadlocks with repeated restarts
If a monitor is started and stopped before the external monitoring thread
has had time to start, a deadlock will occur.

The first thing that the monitoring threads do is read the monitor handle
from the monitor object. This handle is given as the return value of
startMonitor and it is stored in the monitor object. As this can still be
NULL when the monitor thread starts, the threads use locks to prevent
this.

The correct way to prevent this is to pass the handle as the thread
parameter so that no locks are required.
2017-05-04 09:17:48 +03:00
Markus Mäkelä
b1294f083c MXS-1220: Add old diagnostic interface for monitors and authenticators
Added back the old diagnostic entry point in the monitor and authenticator
interfaces.
2017-05-04 09:14:04 +03:00
Markus Mäkelä
5e679aa167 MXS-1220: Implement JSON diagnostics entry point in monitors
All monitors now implement the JSON version of the diagnostics function.
2017-05-04 09:12:15 +03:00
Markus Mäkelä
ad1c05b015 Merge branch '2.1' into develop 2017-04-05 11:35:13 +03:00
Esa Korhonen
a362bd0024 Add parameter backend_connect_attempts to monitor
This number (defaults to 1) sets how many times mon_connect_to_db
will try to connect to a backend before returning an error. Every
connection attempt may take backend_connect_timeout seconds to
complete.

Also refactored code a bit. Renamed mon_connect_to_db to
mon_ping_or_connect_to_db, since it does not connect if the connection
is already alive.
2017-04-03 09:56:22 +03:00
Markus Mäkelä
cbc1e864d9 Use RFC 3986 compliant addresses in log messages
When log messages are written with both address and port information, IPv6
addresses can cause confusion if the normal address:port formatting is
used. The RFC 3986 suggests that all IPv6 addresses are expressed as a
bracket enclosed address optionally followed by the port that is separate
from the address by a colon.

In practice, the "all interfaces" address and port number 3306 can be
written in IPv4 numbers-and-dots notation as 0.0.0.0:3306 and in IPv6
notation as [::]:3306. Using the latter format in log messages keeps the
output consistent with all types of addresses.

The details of the standard can be found at the following addresses:

     https://www.ietf.org/rfc/rfc3986.txt

     https://www.rfc-editor.org/std/std66.txt
2017-03-31 14:12:58 +03:00
Markus Mäkelä
1736aca7f7 Add module level static capabilities
The static capabilities declared in getCapabilities allows certain
capabilities to be queried before instances are created. The intended use
of this capability is to remove the need for the `is_internal_service`
function.
2017-03-20 11:10:08 +02:00
Johan Wikman
5648f708af Update license to BSL 1.1 2017-02-14 21:42:28 +02:00
Esa Korhonen
7d51864402 Clean config.h some more
Moved some typedefs to router.h and server.h, changed a few
constants to these enums. Renamed some types in config.h to
remove "Gateway".

There are still some functions in the public header which are
only used in core, but they seem to fit the theme of public functions
so were not moved.
2017-01-25 16:05:51 +02:00
Esa Korhonen
680401cf8e Rename public types and constants in monitor.h
Preparing to split monitor.h into module and core sections. Also
changed a few comments in monitor.h.
2017-01-17 15:47:13 +02:00
Markus Mäkelä
5b92a1f467 Remove explicit module name from log messages
The module name doesn't need to be logged as MXS_MODULE_NAME will be
automatically added as a prefix to all messages logged by the module.
2017-01-17 12:51:08 +02:00
Markus Mäkelä
2cabcea211 Add definitions of MXS_MODULE_NAME to all modules
All modules now declare a name for the module. This is name is added as a
prefix to all messages logged by a module. The prefix should help
determine which part of the system logs a message.
2017-01-16 11:28:34 +02:00
Markus Mäkelä
a196420c2d Move monitor script processing and launching into the core
This removes parts of the nearly identical code from all monitors.

The removal of monitor type specific event checking is done based on the
assumption that only the monitor that is monitoring the server can be the
cause for a state change. This removes the need to actually check that the
state change is relevant for each monitor and allows the event handling to
be moved into the core.
2017-01-11 14:21:57 +02:00
Johan Wikman
a2a38f952a Add [process|thread] [init|finish] functions to modules
The MXS_MODULDE object now contains optinal pointers for functions
to be called att process and thread startup and shutdown. Since the
functions were added to the end, strictly speaking, all structures
would not have needed to have been modified, but better to be
explicit. In a subsequent change, these will be called.

C++ does not support flexible arrays, so for the time being C++
modules are restricted to 10 parameters. Better approach is to
factor out the parameters to a separate array and then just store
a pointer to that array in MXS_MODULE.
2017-01-05 14:44:02 +02:00
Markus Mäkelä
5a290cb0b8 Use module parameters in monitors
All monitors now declare the parameters that they use. This allows the
core to check the validity of the parameters before they are passed to the
monitor. It also simplifies the processing of the parameters as they are
guaranteed to be valid.
2017-01-05 09:58:11 +02:00
Markus Mäkelä
c96bd64aa8 Rename MODULE_INFO to MXS_MODULE
The MODULE_INFO is now the main object which is used by modules to convey
information to the MaxScale core. The MXS_MODULE name is more apt as it
now contains the actual module definition.

The old MODULES structure was moved into load_utils.c as an internal
implementation and was renamed so that it is not confused with the new
MODULE structure.
2017-01-03 18:01:14 +02:00
Markus Mäkelä
b00e0328d5 Create a macro for module declarations
The modules are now declared with a common macro. This allows future
additions to the module loading process while also making the loaded
symbol name a constant.
2017-01-03 18:01:13 +02:00
Markus Mäkelä
ae0577c695 Move module object inside MODULE_INFO
This allows modules to only expose one entry point with a consistent
signature. In the future, this could be used to implement declarations of
module parameters.
2017-01-03 18:01:13 +02:00
Markus Mäkelä
6c53999c97 Combine ModuleInit and GetModuleObject
The two functions can be combined into one as both are called only
once. This removes the need for the explicit ModuleInit function.
2017-01-03 18:01:13 +02:00
Markus Mäkelä
7df29aa1ec Move version entry point into MODULE_INFO
The MODULE_INFO can easily hold the version information of the
module. This removes the need for a explicit version entry point.
2017-01-03 18:01:13 +02:00
Esa Korhonen
7e9db7ed0c Have server status updates applied during monitor loop
Previously, server status changes from MaxAdmin would be set immediately
as long as the server lock could be acquired. This meant that it might take
several seconds until the next monitor pass is executed. Usually, this was
fine but in some situations we would want the monitor to run immediately
after the change (MXS-740 and Galera). This patch changes the logic of
setting and clearing status bits to a delayed mode: changes are first applied
to a "status_pending"-variable, and only once the monitor runs will the
setting be applied. To reduce the delay, the monitor now has a flag
which is checked during sleep (between short 0.1s naps). If set, the
sleep is cut short.

If a server is not monitored, the status bits are set directly.

There is a small possibility of a race condition: If a monitor is stopped or
destroyed before the pending change is applied, the change is forgotten.
2016-12-19 10:19:23 +02:00
ekorh475
259e944b3d Server status changes now happen under a lock
MXS-873 To prevent monitors and MaxAdmin from interfering with each other,
changes to the server status flags now happen under a lock. To avoid
interfering with monitor logic, the monitors now acquire locks to all
of their servers at the start of the monitor loop and release them
before sleeping.
2016-12-12 15:04:05 +02:00
Markus Makela
72622bc92f MXS-977: Move common diagnostic code to the core
Almost all monitors printed the same diagnostic output inside the
modules. This should be a part of the core, not the modules themselves.
2016-11-17 12:36:44 +02:00
Markus Makela
3c15b58891 Merge branch '2.0' into develop-2.0-merge 2016-11-15 00:09:24 +02:00
Johan Wikman
e41589be10 Move headers from server/include to include/maxscale
- Headers now to be included as <maxscale/xyz.h>
- First step, no cleanup of headers has been made. Only moving
  from one place to another + necessary modifications.
2016-10-13 16:19:20 +03:00
Johan Wikman
3eb25df676 Update monitor APIs
No need to use void* as the types of the arguments in the monitor
functions as the types are known and will always be the same.
2016-08-19 11:21:01 +03:00
Johan Wikman
cf7988c8e3 Move all monitors into subdirs of their own
Each monitor module now resides in a subdirectory of its own.
The name of the subdirectory is the same as the name of the
library in the module's CMakeLists.txt file.
2016-08-18 13:35:28 +03:00