The configuration used an invalid parameter name which caused the two MaxScales to use the same directory for persisted configurations. The test also tried to sync with the wrong server causing the same listener to be created twice on the same port but on different MaxScales. Cleaned up the startup and shutdown scripts to always start from a clean state.
35 lines
816 B
Bash
Executable File
35 lines
816 B
Bash
Executable File
#!/bin/bash
|
|
|
|
#
|
|
# This script is run before each test block. It starts MaxScale and waits for it
|
|
# to become responsive.
|
|
#
|
|
|
|
maxscaledir=$MAXSCALE_DIR
|
|
|
|
test -z "$MAXSCALE_DIR" && exit 1
|
|
|
|
rm -r $maxscaledir/lib/maxscale
|
|
rm -r $maxscaledir/cache/maxscale
|
|
rm -r $maxscaledir/run/maxscale
|
|
test -f /tmp/maxadmin.sock && rm /tmp/maxadmin.sock
|
|
|
|
mkdir -m 0755 -p $maxscaledir/lib/maxscale/maxscale.cnf.d
|
|
mkdir -m 0755 -p $maxscaledir/cache/maxscale
|
|
mkdir -m 0755 -p $maxscaledir/run/maxscale
|
|
mkdir -m 0755 -p $maxscaledir/log/maxscale
|
|
|
|
# Start MaxScale
|
|
$maxscaledir/bin/maxscale -df $maxscaledir/maxscale.cnf &>> $maxscaledir/maxscale.output &
|
|
pid=$!
|
|
|
|
# Wait for MaxScale to start
|
|
for ((i=0;i<60;i++))
|
|
do
|
|
$maxscaledir/bin/maxadmin help >& /dev/null && break
|
|
sleep 0.1
|
|
done
|
|
|
|
# Give MaxScale some time to settle
|
|
sleep 1
|