60 lines
1.9 KiB
Markdown
60 lines
1.9 KiB
Markdown
# NDB Cluster Monitor
|
|
|
|
## Overview
|
|
|
|
The MySQL Cluster Monitor is a monitoring module for MaxScale that monitors a MySQL Cluster. It assigns a NDB status for the server if it is a part of a MySQL Cluster.
|
|
|
|
## Configuration
|
|
|
|
A minimal configuration for a monitor requires a set of servers for monitoring and a username and a password to connect to these servers. The user requires the REPLICATION CLIENT privilege to successfully monitor the state of the servers.
|
|
|
|
```
|
|
[MySQL Cluster Monitor]
|
|
type=monitor
|
|
module=ndbclustermon
|
|
servers=server1,server2,server3
|
|
user=myuser
|
|
passwd=mypwd
|
|
|
|
```
|
|
|
|
## Optional parameters for all monitors
|
|
|
|
Here are optional parameters that are common for all the monitors.
|
|
|
|
### `monitor_interval`
|
|
|
|
This is the time the monitor waits between each cycle of monitoring. The default value of 10000 milliseconds (10 seconds) should be lowered if you want a faster response to changes in the server states. The value is defined in milliseconds and the smallest possible value is 100 milliseconds.
|
|
|
|
```
|
|
monitor_interval=2500
|
|
```
|
|
|
|
### `backend_connect_timeout`
|
|
|
|
This parameter controls the timeout for connecting to a monitored server. It is in seconds and the minimum value is 1 second. The default value for this parameter is 3 seconds.
|
|
|
|
```
|
|
backend_connect_timeout=6
|
|
```
|
|
|
|
### `backend_write_timeout`
|
|
|
|
This parameter controls the timeout for writing to a monitored server. It is in seconds and the minimum value is 1 second. The default value for this parameter is 2 seconds.
|
|
|
|
```
|
|
backend_write_timeout=4
|
|
```
|
|
|
|
### `backend_read_timeout`
|
|
|
|
This parameter controls the timeout for reading from a monitored server. It is in seconds and the minimum value is 1 second. The default value for this parameter is 1 seconds.
|
|
|
|
```
|
|
backend_read_timeout=2
|
|
```
|
|
|
|
### Common Monitor Parameters
|
|
|
|